Skip to content
Home > Series > 3Phase > AYC

AYC Series

High Performance 3-Phase RFI Power Line Filters for WYE Applications

UL Recognized

Catalog Data Sheet

AYC Series

The AYC series filters are designed for 3-phase, four-wire,WYE wiring applications. These cost-effective filters help better protect electronic equipment in industrial applications.

The series offers filtering up to 180 amps maximum and is used in 3-phase, noisy industrial applications such as frequency converters. The AYC series is designed to comply with International Standards including EN133200 and UL 1283.

Electrical Schematic

Resistor location for reference only

Specifications

Maximum leakage current, each line to ground:
  @ 120 VAC 60 Hz:  
  16A 62mA
  25/36A 68mA
  63/80/110/150A 74mA
  180A 111mA
  @ 250 VAC 50 Hz:  
  16A 106mA
  25/36A 118mA
  63A 128mA
  80/110/150A 129mA
  180A 192mA
     
Hipot rating (one minute):
  line to ground 1850VDC
  line to line 1850VDC
  line to neutral 1450VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 480 VAC
     
Rated Current: 16A to 180A *
  * refer to part number for rating
Minimum insertion loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .1 .5 1 5 10 30

16A 23 66 82 88 82 79 55 21
25A 26 68 83 93 88 68 45 4
36A 18 61 78 96 91 71 49 7
63A 11 57 72 90 86 68 44 4
110A 10 51 60 88 84 74 50 12
150A* 0 50 57 82 79 75 51 7
150A 1 51 55 85 82 84 51 11
180A 3 53 55 97 89 81 56 20

Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .1 .5 1 5 10 30

16A 21 32 54 90 86 73 72 47
25A 23 33 60 100 95 87 70 38
36A 25 37 51 94 87 69 58 17
63A 27 45 41 84 77 63 61 43
110A 27 35 39 75 72 51 44 31
150A* 28 37 42 74 67 52 45 30
150A 28 40 42 73 66 51 44 31
180A 30 41 50 70 64 49 42 26

* 150AYC10B-95 model only

Case Styles

16, 25, 36, 63 AYC10B

80, 110 ,150 AYC10B / -95

180AYC10B

 

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) (max.) ± .078
± .2
16AYC10B 6.69 4.37 2.56 4.92 2.76
170.0 111.0 65.0 125.0 70.0

25AYC10B 9.96 5.08 2.52 5.71 4.53
246.0 129.0 64.0 145.0 115.0

36AYC10B 10.35 5.08 2.52 5.71 4.53
263.0 129.0 64.0 145.0 115.0

63AYC10B 10.89 5.08 2.52 5.71 4.53
279.0 129.0 64.0 145.0 115.0

80/110/150
AYC10B
12.09 5.55 5.55 6.10 4.53
307.0 141.0 141.0 155.0 115.0

180AYC10B 15.71 5.55 5.55 6.10 3.25
399.0 141.0 141.0 155.0 82.5

Terminals

    Type (qty.) Torque in. lb.
16AYC10B
GroundTerminals   M5 (2) 26 max.
Phoenix Contacts   VDFK4 (8) 5.31 min.
Accepts 12 AWG stranded wire. Strip length 0.315

25AYC10B
Ground Terminals   M5 (2) 26 max
Phoenix Contacts   VDFK6 (8) 13.28 min.
Accepts 10 AWG stranded wire. Strip length 0.354

36AYC10B
Ground Terminals   M5 (2) 26 max.
Phoenix Contacts   HDFK10 (8) 13.28 min
Accepts 8 AWG stranded wire. Strip length 0.433

63AYC10B
Ground Terminals   M6 (2) 53 max.
Phoenix Contacts   HDFK16 (8) 17.70 min.
Accepts 6 AWG stranded wire. Strip length 0.630

80/110/150 AYC10B
Terminals   M10 (2) 58 max
Phoenix Contacts   HDFK50 (8) 53.10 min
Accepts 1 AWG stranded wire. Strip length 0.945

150AYC10B-95 / 180AYC10B
Ground Terminasl   M10 (2) 58 max
Phoenix Contacts   HDFK95 (8) 132 min
Accepts 0 AWG stranded wire. Strip length 1.063

 

Ordering and Design Information

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.

16AYC10B 110AYC10B
25AYC10B 150AYC10B
36AYC10B 150AYC10B-95
63AYC10B 180AYC10B
80AYC10B  

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.