FFA Series

  • AC feedthrough filters
  • Current Ratings from 10 to 300A
  • Designed to meet the very stringent safety requirements
    of EN133200 class Y2 including the 5000V pulse test
  • Custom versions available

Ordering Information

Filter Options / Specifications

Capacitor ID Value
(nF ± 20%)
Inductance
(nH)
Maximum
Leakage Current
(mA) *
DC
Resistance
(mΩ) Max.
BA 2 x 4.7 70 0.9 6
CA 2 x 10 70 1.9 4
CE 2 x 10 140 1.9 7
DG 2 x 22 170 4.2 4
DH 2 x 22 180 4.2 4
GB 2 x 47 80 8.9 3
GJ 2 x 47 210 8.9 9
HC 2 x 100 90 19 2
HD 2 x 100 120 19 1
HF 2 x 100 160 19 <1
HN 2 x 100 250 19 6
JK 2 x 150 240 29 3
NP 2 x 470 330** 89 <2
PP 2 x 1000 330 188 <2
* @ 250 VAC 60 Hz
** 240 for 100 amp version

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

Standard Performance High Performance Extended Performance
10FFA6-BA 10FFA6-CE 10FFA6-GJ
16FFA6-CA 16FFA6-DG 16FFA6-HN
32FFA6-CA 32FFA6-DH 32FFA6-HN
63FFA6-GB 63FFA6-JK 63FFA6-NP
100FFA6-HC 100FFA6-NP 100FFA6-PP
200FFA6-HD 200FFA6-NP 200FFA6-PP
250FFA6-HF 250FFA6-NP 250FFA6-PP
300FFA6-HF 300FFA6-NP 300FFA6-PP

 

 

Specifications

Rated voltage (max.): 250 VAC
   
Operating Frequency: 50/60 Hz
   
Rated Current: 10 to 300A
 
Test Voltage (two seconds): 5000 VDC
   
Capactior Class (EN133200): Designed to meet Y2
   
Pulse Test (EN133200): 5000V Peak
   
Insulation Resistance (within 1 minute):
For C <0.33μF, R> 15000MΩ
For C>0.33μF, RC(MΩ*μF)>5000s
   
Operating Ambient Temperature Range (at rated current Ir):

10 to 100 Amps:
200 Amps:
250 & 300 Amps:

-40°C to +60°C
-40°C to +50°C
-40°C to +40°C
   
Category Temperature Range: -40°C to +85°C
   
Current Derating Above Ambient:  
10-100A: For temperature θ Iθ = IR √(85-θ)/25
200A: For temperature θ Iθ = IR √(85-θ)/35
250 & 300A: For temperature θ Iθ = IR √(85-θ)/45
   
Climatic Category: 40/85/21
   
MTBF: Typically > 5 million hours
   
Insulating Materials Flammability Rating: UL 94V-0
   
Case and Terminal Material / Finish: Nickel Plated Brass

Electrical Schematic

 

Case Styles

 

T1 - Terminal Thread
Part Number(s) Thread  Torque
(in-lb.)
10FFA6-BA/CE/GJ M3 4
16FFA6-CA/DG/HN
32FFA6-CA/DH/HN
M4 11
63FFA6-GB/JK/NP M6 22
100FFA6-HC/NP/PP M8 44
200FFA6-HD/NP/PP M10 70
250FFA6-HF/NP/PP M12 97
300FFA6-HF/NP/PP M16 177
T2 - Mounting Thread
Part Number(s) Thread Torque
(in-lb.)
10FFA6-BA/CE/GJ
16FFA6-CA
32FFA6-CA
M12 x 1 35
16FFA6-DG/HN
32FFA6-DH/HN
63FFA6-GB
M16 x 1 62
63FFA6-JK
100FFA6-HC
M20 x 1 89
100FFA6-NP
200FFA6-HD
M24 x 1 124
63FFA6-NP
100FFA6-PP
200FFA6-NP/PP
M27 x 1.5 142
250FFA6-HF/NP/PP
300FFA6-HF/NP/PP
M32 x 1.5 212

 

 

Case Dimensions

Part Number A B C D E F
± .04 ± .02 ±.04 ± .04 ± .08 ref.
1 0.5 1 1 2
10FFA6-BA 3.86 0.79 2.24 0.47 0.63 0.67
98 20 57 12 16 17
16FFA6-CA
32FFA6-CA
4.17 0.79 2.40 0.47 0.71 0.67
106 20 61 12 18 17
63FFA6-GB 6.30 0.98 3.70 0.55 1.02 0.87
160 25 94 14 26 22
100FFA6-HC 7.24 1.26 4.09 0.63 1.26 1.06
184 32 104 16 32 27
200FFA6-HD 8.23 1.50 4.41 0.75 1.57 1.06
209 38 112 19 40 27
250FFA6-HF
300FFA6-HF
7.87 2.13 3.66 0.75 1.81 1.57
200 54 93 19 46 40
10FFA6-CE 4.21 0.79 2.60 0.47 0.63 0.67
107 20 66 12 16 17
16FFA6-DG
32FFA6-DH
4.57 0.98 2.72 0.55 0.71 0.87
116 25 69 14 18 22
63FFA6-JK 6.81 1.26 4.13 0.63 1.02 1.06
173 32 105 16 26 27
100FFA6-NP 8.98 1.50 5.71 0.75 1.26 1.06
228 38 145 19 32 27
200FFA6-NP 9.57 2.13 5.75 0.75 1.57 1.57
243 54 146 19 40 40
250FFA6-NP
300FFA6-NP
10.51 2.13 6.30 0.75 1.81 1.57
267 54 160 19 46 40
10FFA6-GJ 5.51 0.79 3.90 0.47 0.63 0.67
140 20 99 12 16 17
16FFA6-HN
32FFA6-HN
5.83 0.98 3.98 0.55 0.71 0.87
148 25 101 14 18 22
63FFA6-NP 7.44 2.13 4.65 0.75 1.02 1.57
189 54 118 19 26 40
100FFA6-PP 8.94 2.13 5.67 0.75 1.26 1.57
227 54 144 19 32 40
200FFA6-PP 9.57 2.13 5.75 0.75 1.57 1.57
243 54 146 19 40 40
250FFA6-PP
300FFA6-PP
10.51 2.13 6.30 0.75 1.81 1.57
267 54 160 19 46

40

 

Performance Data

Typical Insertion Loss in dB:
Measured in closed 50 ohm system
 
Common Mode / Asymmetrical (Line to Ground)

Capacitor ID Frequency - MHz
0.01 0.03 0.1 0.3 1 10 100 1000

BA - - - - 4 18 80 100
CA - - 2 4 10 22 65 100
CE - - 2 3 10 28 65 100
DG - - 3 7 15 40 72 100
DH - - 3 7 15 40 72 100
GB - - 6 11 21 50 85 100
GJ - - 5 12 21 60 90 100
HC - 2 10 18 27 60 100 100
HD - 2 10 18 27 60 100 100
HF - 2 10 18 27 60 100 100
HN 2 4 10 17 24 75 90 100
JK 3 8 15 21 28 72 100 100
NP 7 15 24 31 44 80 100 100
PP 12 20 29 33 56 80 100 10

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.