Skip to content
Home > Series > IEC > EBF

EBF Series

Accessory Outlet Filter


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

EBF Series

  • Accessory IEC 60320-1 C13 filtered outlet
  • Allows connection of accessories while filtering noise between a system and the accessory
  • Enhanced performance across the frequency range
  • Grounded connection
  • Suitable for international usage

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

1EBF1 1EBF4
3EBF1 3EBF4
6EBF1 6EBF4
10EBF1 10EBF4

 

 

Specifications

Maximum leakage current, each Line to Ground:
  @ 120 VAC 60 Hz .25 mA
  @ 250 VAC 50 Hz .50 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 1A to 10A
   
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

 

Case Styles

EBF1

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
  Load Outlet (1): IEC60320-1 C13
  Terminals (2): .250 [6.35] with .07 [1.8] Dia. hole
  Ground Terminal (1): .250 [6.35] with .07 x .16 [1.8 x 4.1] slot

EBF4

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
  Load Outlet (1): IEC60320-1 C13
  Wire Leads (3): 10.0 [254.0] min., 18AWG, UL1015

 

 

Recommended Panel Cutouts

Front Mount Only
Tolerance + .008 [.203] / - .000 [.000]

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .010 (max.)
± .25
EBF1 2.57 1.33 1.00 1.575 1.99
65.3 33.8 25.4 40.01 50.5

EBF4 2.09 1.39 1.16 1.575 1.99
53.01 35.31 29.46 40.01 50.5

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 
1EBF

3EBF

6EBF

10EBF

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.05 .15 .5 1 5 10 30

1A 23 32 41 47 47 47 40
3A 10 19 30 36 48 50 47
6A 1 10 22 28 42 48 47
10A 1 5 14 20 32 38 47

 
Current Rating Frequency - MHz
.15 .5 1 3 5 10 30

1A 3 14 23 41 47 50 44
3A 2 11 14 25 38 44 40
6A 2 10 14 20 33 42 40
10A 2 10 16 19 19 39 40

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.