EEA Series
- Compact single stage EMI filter with IEC 60320-1 C14 inlet
- Two element circuit provides basic attenuation
- Same performance as the EF Series
- Available in three terminal configurations
- Supersedes EF Series
EEB Series
- Compact EMI filter with IEC 60320-1 C14 inlet
- Two element circuit provides extended attenuation
- Extended differential mode performance
- Available in three terminal configurations
EAS & EBS Models
- Same performance as EEA and EEB Series
- Snap–in mounting
- Spade terminals
EAH & EBH Models
- Same size as EEA and EEB
- Minimal leakage current suitable for medical applications
- Flange mounted
- Spade terminals
Ordering Information

Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
|
EEA/EEB Models
EAS/EBS Models |
EAH/EBH Models |
| |
@ 120 VAC 60 Hz |
.22 mA |
2 µA |
| |
@ 250 VAC 50 Hz |
.38 mA |
5 µA |
| |
|
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
|
2250 VDC |
| |
Line to Line |
|
1450 VDC |
| |
|
|
|
| Operating Frequency: |
|
50 / 60 Hz |
| |
|
|
|
| Rated voltage (max.): |
|
250 VAC |
| |
|
|
|
| Rated Current: |
|
1A to 10A |
| |
|
| Operating Ambient Temperature Range (at rated current Ir): |
| |
|
-10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45
|
Electrical Schematic

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

FA601: Insulating Shroud
 

EAS/EBS Models |
Case Styles
EEA1, EEB1, EAH1 & EBH1

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
|
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
Terminals (2): |
.250 [6.35] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.35] with .07 x .16 [1.8 x 4.1] slot |
EEA2 & EEB2

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
|
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
Terminals (2): |
.250 [6.35] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.35] with .07 x .16 [1.8 x 4.1] slot |
EEAP & EEBP

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
|
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
PC board pins (3): |
.031 [.07] square, ± .003[.07] |
EAS1 & EBS1

| Typical Dimensions: |
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
Terminals (2): |
.250 [6.35] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.35] with .07 x .16 [1.8 x 4.1] slot |
|
|
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
±.010 |
(max.) |
| ± .25 |
EEA1, EEB1,
EAH1, EBH1 |
2.15 |
1.12 |
0.81 |
1.575 |
1.98 |
| 54.6 |
28.4 |
20.6 |
40.01 |
50.3 |
|
| EEA2, EEB2 |
1.54 |
1.12 |
0.81 |
1.575 |
1.98 |
| 39.1 |
28.4 |
20.6 |
40.01 |
50.3 |
|
| EEAP, EEBP |
1.54 |
1.12 |
0.81 |
1.575 |
1..98 |
| 39.1 |
28.4 |
20.6 |
40.01 |
50.3 |
|
| EAS1, EBS1 |
2.20 |
1.15 |
.96 |
1.185 |
1.41 |
| 55.88 |
29.2 |
24.38 |
30.10 |
35.81 |
|
Recommended Panel Cutouts
EEA, EEB, EAH, EBH

Note 1: EEA1, EEB1, EAH1, EBH1 can be front or back mounted
Note 2: EEA2, EEB2, EEAP and EEBP can be back mounted only
EAS, EBS

Front Mount only
| Panel Thickness |
G Dim. ± .002 [.05] |
| 0.031 - 0.052 [0.79 - 1.32] |
1.260 [32.00] |
| 0.046 - 0.068 [1.17 - 1.73] |
1.350 [34.29] |
PC Board Layout

|