Skip to content
Home > Series > IEC > EF

EF Series

Compact RFI Filter with IEC Connector


UL Recognized
CSA Certified
VDE Approved

15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC

Catalog Data Sheet
Printer friendly version

 

EF Series

  • Compact single stage EMI filter with IEC 60320-1 C14 inlet
  • Two element circuit provides basic attenuation
  • Available with an internal ground-circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies
  • Superseded by the EEA Series

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

1EF1F 1EF2F 1EF4 1EF8
3EF1F 3EF2F 3EF4 3EF8
6EF1F 6EF2F 6EF4 6EF8
10EF1F      
15EF1F      
Ground Circuit Inductor Versions
10EF1FC      

 

 

 

 

Specifications

Maximum leakage current, each Line to Ground:
  @ 120 VAC 60 Hz .21 mA
  @ 250 VAC 50 Hz .36 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 1A to 15A
   
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

Accessories

GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

FA601: Insulating Shroud

Case Styles

EF1F & EF1FC

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia.
  Line Inlet (1) IEC60320-1 C14
  Terminals (2): .250 [6.35] with .07 [1.8] Dia. hole
  Ground Terminal (1): .250 [6.35] with .07 x .16 [1.8 x 4.1] slot

 

EF2F

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia.
  Line Inlet (1) IEC60320-1 C14
  Terminals (2): .250 [6.35] with .07 [1.8] Dia. hole
  Ground Terminal (1): .250 [6.35] with .07 x .16 [1.8 x 4.1] slot

EF4

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia.
  Line Inlet (1) IEC60320-1 C14
  Wire Leads (3): 4.0 [101.6] Min., 18AWG, UL1015

 

 

 

EF8


Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia.
  Line Inlet (1) IEC60320-1 C14
  Wire Leads (3): 4.0 [101.6] Min., 18AWG, UL1015

Recommended Panel Cutouts

Note 1: ED1 and ED8 allow for front or back mounting
Note 2: ED2 and ED4 allow for back mounting only

Case Dimensions

Part No. A B C D E F
(max.) (max.) (max.) ± .015 (max.) (ref)
± .38
1EF1F, 3EF1F,
6EF1F
2.20 1.19 0.81 1.575 1.98  
55.9 30.2 20.6 40.01 50.3  

1EF2F, 3EF2F,
6EF2F
1.55 1.19 0.85 1.575 1.98  
39.4 30.2 21.6 40.01 50.3  

1EF4, 3EF4,
6EF4
1.55 1.19 0.85 1.575 1.98 .295
39.4 30.2 21.6 40.01 50.3 7.5

1EF8, 3EF8,
6EF8
1.55 1.19 0.81 1.575 1.98 .295
39.4 30.2 20.6 40.01 50.3 7.5

10EF1F, 10EF1FC,
15EF1F
2.62 1.19 0.81 1.575 1.98  
66.5 30.2 20.6 40.01 50.3  

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 
1EF

3EF

6EF

10EF

15EF

 

 

 

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)    

   
Minimum Insertion Loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.15 .5 1 5 10 30

EF1F, EF2F            
1A 22 35 40 46 50 49
3A 15 25 30 45 50 54
6A 9 20 25 41 45 50
10A 8 15 20 34 39 44
15A - 6 12 20 25 25
EF4, EF8            
1A 22 35 40 46 50 49
3A 15 25 30 45 50 54
6A 9 20 25 41 45 47
EF1FC            
10A 8 15 20 34 39 44

   

 

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.