| Compact RFI Filter with IEC Connector for Higher Frequency |
  
UL Recognized
CSA Certified
VDE Approved
15A versions are tested by Underwriters Laboratories
to US and Canadian requirements
and are
VDE approved at 10A, 250VAC
20A versions are tested by Underwriters Laboratories
to US and Canadian requirements
and are
VDE approved at 16A, 250VAC
Catalog Data Sheet 
Printer friendly version |
|
 |
EJT Series
- Superior EMI filter with IEC 60320-1 inlet
- Double three element differential mode circuit
attenuates noise up to 1GHz
- Up to 15A with IEC 60320-1 C14 inlet
- 20A rating with IEC 60320-1 C20 inlet
- Spade terminals or wire leads
Ordering Information

Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
|
1-15 Amp |
20 Amp |
| |
@ 120 VAC 60 Hz |
.25 mA |
.22 mA |
| |
@ 250 VAC 50 Hz |
.43 mA |
.40 mA |
| |
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
|
2250 VDC |
| |
Line to Line |
|
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
250 VAC |
| |
|
|
| Rated Current: |
1A to 20A |
| |
|
| Operating Ambient Temperature Range (at rated current Ir): |
| |
|
-10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45
|
Electrical Schematic

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

FA601: Insulating Shroud
 
|
| Case Styles |
EJT1 (1-15 amp version)

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia.
|
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
Terminals (2): |
.250 [6.35] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.35] with .07 x .16 [1.8 x 4.1] slot |
20EJT1

| Typical Dimensions: |
| |
Mounting holes (2): |
.126 [3.20] Dia. |
| |
Line Inlet (1) |
IEC60320-1 C20 |
| |
Terminals (2): |
.250 [6.35] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.35] with .07 x .16 [1.8 x 4.1] slot |
EJT8

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia.
|
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
Wire Leads (3): |
4.0 [101.6] Min. 18AWG, UL1015 |
|
|
20EJT8

| Typical Dimensions: |
| |
Mounting holes (2): |
.126 [3.20] Dia.
|
| |
Line Inlet (1) |
IEC60320-1 C14 |
| |
Wire Leads (3): |
4.0 [101.6] Min. 18AWG, UL1015 |
Recommended Panel Cutouts

Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
(max.) |
(max.) |
| EJT1 |
2.74 |
1.19 |
0.875 |
1.575 |
1.98 |
| 69.6 |
30.2 |
22.2 |
40.0 |
50.3 |
|
| EJT8 |
2.1 |
1.19 |
0.875 |
1.575 |
1.98 |
| 56.6 |
30.2 |
22.2 |
40.0 |
50.3 |
|
| 20EJT1 |
3.8 |
1.350 |
1.18 |
1.654 |
2.087 |
| 96.52 |
34.29 |
29.99 |
42.01 |
53.00 |
|
| 20EJT8 |
3.2 |
1.350 |
1.18 |
1.654 |
2.087 |
| 81.28 |
34.29 |
29.99 |
42.01 |
53.00 |
|
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
1EJT

|
3EJT

|
6EJT

|
10EJT

|
15EJT

|
20EJT

|
|
|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
5 |
10 |
30 |
100 |
1000 |
|
| 1A |
27 |
33 |
40 |
59 |
65 |
65 |
61 |
14 |
| 3A |
22 |
30 |
34 |
57 |
63 |
69 |
61 |
10 |
| 6A |
13 |
21 |
27 |
51 |
60 |
65 |
69 |
14 |
| 10A |
7 |
14 |
21 |
43 |
52 |
61 |
61 |
14 |
| 15A |
4 |
10 |
15 |
38 |
48 |
63 |
63 |
14 |
| 20A |
- |
8 |
15 |
42 |
50 |
60 |
58 |
14 |
|
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
5 |
10 |
30 |
100 |
1000 |
|
| 1A |
10 |
20 |
23 |
43 |
52 |
65 |
45 |
14 |
| 3A |
10 |
20 |
24 |
41 |
51 |
59 |
52 |
17 |
| 6A |
10 |
21 |
24 |
37 |
48 |
65 |
55 |
20 |
| 10A |
10 |
21 |
25 |
28 |
44 |
63 |
53 |
18 |
| 15A |
10 |
20 |
26 |
25 |
36 |
56 |
45 |
23 |
| 20A |
9 |
20 |
26 |
40 |
35 |
48 |
50 |
10 |
|
|
|