Power Entry Module with Voltage Selection and Fusing


UL Recognized
CSA Certified

Catalog Data Sheet
Printer friendly version

 

J Series

  • Power entry module with North American style 3AG fuse holder
  • 2 or 4 voltage selection
  • Compact snap-in design
  • Two element circuit provides basic EMI attenuation
  • Available with minimal leakage current suitable for medical applications (HJ models)
  • Also available without filter (VJ models)

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

Non-filtered models
6VJ1 6VJ1-2
General Purpose Filters
6J4 6J4-2
Medical Filters
6HJ4-4 6HJ4-2

Accessories

GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

JA302: 2 Voltage Select Card
Comes standard with 6VJ1-2, 6J4-2 and 6HJ4-2

JA304: 4 Voltage Select Card
Comes standard with 6VJ1, 6J4 and 6HJ4-4

JA403: Mounting clips for .105 - .125" panels

JA410-419: Equipment Rating Labels
Self-adhesive, available in multiples of 40, Specify part number


Part
Number
A
VA Max.
B
Fuse
100/120(115)
C
Fuse
220/240(230)

JA410 25 250 mA 125 mA
JA411 50 500 mA 250 mA
JA412 100 1A 500 mA
JA413 200 2A 1A
JA414 250 2.5A 1.25A
JA415 300 3A 1.5A
JA416 400 4A 2A
JA417 500 5A 2.5A
JA418 600 6A 3A
JA419 Assortment, 5 of each label JA410-418

Label Height: .210"
Label Width: 2.330"

JA500: Voltage Selector Card Extractor Tool

 

 

Specifications

Maximum leakage current, each Line to Ground:
    6J4
Models
6HJ4 or
non-filtered models
  @ 250 VAC 50 Hz
500 µA 5 µA
     
Hipot rating (one minute):
  Line to Ground (VAC) 1550 VAC
  Line to Line (VDC) 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Operating voltages:
  suffix -1 or -4 models: 100, 120, 220 or 240 VAC
  suffix - 2 models: 115 or 230 VAC
     
Rated Current: 2 to 6A
   
Required Fuse:

.25 x 1.25
(not included)

Electrical Schematics

6VJ1 & 6VJ1-2

6J4 & 6J4-2

6HJ4-4 & 6J4-2

Note 1: Jumper required if only SPST power switch is used
Note 2: Jumpers required if no input filtering is used
Note 3: Use only 120V and 240V positions for 2 volt selection units

Voltage Selection

Open cover door and slide fuse-pull lever to left. Select operating voltage by orienting voltage selection card with the desired voltage on top left side. Push card firmly into module slot. Slide fuse-pull lever to right into normal position and re-insert fuse into holders.

Use caution in selecting correct fuse value.

 

Case Styles

Non-filtered Models

Filtered Models

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Terminals: .110 [2.79]
 

Recommended Panel Cutouts

Standard units mount in panel thickness of .060 - .090 [1.52 -2.29]
JA403 Mounting clips for .105 - .125" panels available separately
Fuse cover door shown in open position

Case Dimensions

Part No. A B C D
(max.) (max.) (max.) (max.)

Unfiltered
6VJ1, 6VJ1-2

2.68 1.52 1.17 1.23
68.1 38.6 29.7 31.2

6J4, 6J4-2,
6HJ4-4, 6HJ4-2
2.75 1.87 1.17 1.58
69.9 47.5 29.7 40.1

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

6J4

6HJ4

 

 

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)    

   
Model No. Frequency - MHz
.15 .5 1 5 10 20 30

6J4 9 20 25 41 45 45 48
6HJ4 9 11 15 19 13 12 10

   

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
 

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.