L Series

Dual Configuration Power Entry Module


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

L Series

  • Power entry module with switch or fuse
  • For 10A capability and high performance filtering see the P Series
  • Two element circuit provides extended EMI attenuation similar to EAB inlet filter
  • North American or metric fuse holders
  • Available with minimal leakage current for
    medical applications (HL models)

Ordering Information

 

 

Specifications

Maximum leakage current, each Line to Ground :
    DL
Models
HL
Models
  @ 120 VAC 60 Hz: 0.25 mA 2 µA
  @ 250 VAC 50 Hz
0.50 mA 5 µA
     

Hipot rating (one minute):

  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Operating voltages:
  1S & 1SC Suffix (fixed) 250 VAC Max.
  4 & 4C Suffix (selectable) 100, 120, 220, 240 VAC
     
Rated Current:
  2EDL & 2EHL 2A
Required Fuse(s):  
  North American: one .25 x 1.25"(not included)
  Metric: two 5 x 20mm (not included)
   
Switch:

DPST
10,000 operations at 51A max. inrush

Voltage Selection

To change selected voltage: disconnect the power cord; open cover using a small blade screwdriver or similar tool; insert the tool into the voltage selection slot and remove wheel from unit; select desired voltage; replace wheel into unit and close cover, making sure the selected voltage appears in connector window.

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

Available Part Numbers North American Fusing Metric Fusing
Flange Mount Snap-In Flange Mount Snap-In
Non-Filtered Single Voltage,
Switched
6EL1S 6EL1SC 6EL1SM 6EL1SCM
4 Voltage Select,
No Switch
6EL4 6EL4C 6EL4M 6EL4CM
General
Purpose Filter
Single Voltage,
Switched
2EDL1S 2EDL1SC 2EDL1SM 2EDL1SCM
4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM
6EDL1S 6EDL1SC 6EDL1SM 6EDL1SCM
4 Voltage Select,
No Switch
2EDL4 2EDL4C 2EDL4M 2EDL4CM
4EDL4 4EDL4C 4EDL4M 4EDL4CM
6EDL4 6EDL4C 6EDL4M 6EDL4CM
Medical Filter Single Voltage,
Switched
6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM
4 Voltage Select,
No Switch
6EHL4 6EHL4C 6EHL4M 6EHL4CM

Accessories

GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

LA303: Voltage Select Wheel, 3 position

Selection drum for use with L4 models.
Marked with 110V, 220V and 240V

LA304: Voltage Select Wheel, 4 position

Selection drum for use with L4 models.
Marked with 100V, 110V, 220V and 240V.
One LA304 comes standard with each L4 model.

LA400: Blank insert
Blank to replace switch in single voltage models

LA601: Insulating Boot
Plastic shroud to cover back of module to prevent inadvertent access

Replacement Fuse Holders

LA200: North American Fuseholder
Accommodates one .25 x 1.25" fuse

LA201: Metric Fuseholder
Accommodates one 5 x 20mm metric fuse

 

 

Electrical Schematics

DL Models

Single Voltage, Switched (DL1S)

4 Voltage Select, No-Switch (DL4)

HL Models

Single Voltage, Switched (HL1S)

4 Voltage Select, No-Switch (HL4)

 

Case Styles

Flange Models, Non-filtered

Switched model shown, for non-switched detail refer to snap-in models

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Backplate Terminals: .110 [2.79]
  Switch Terminals: .187 [4.765] with .07 x .16 [1.8 x 3.8] slot

Flange Models, Filtered

Switched model shown, for non-switched detail refer to snap-in models
Metric fuse models have an additional jumper from filter to module

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Backplate Terminals: .110 [2.79]
  Switch Terminals: .187 [4.765] with .07 x .16 [1.8 x 3.8] slot

Recommended Panel Cutouts

Notes:

(1) For panel thickness of .031 – .079 [0.8 – 2.0]
(2) For panel thickness of .083 – .126 [2.1 – 3.2]
(3) Mounting Holes .126 [3.20] Dia. for flange mounted versions only
(4) For Snap-In applications, the 1.12 [28.5] sides of the cutout must have a .02 [.508] radius on the installation side. Not required for flange mount versions.

 

 

 

Snap-in Models, Non-filtered

Non-switched model shown, for switched detail refer to flange models

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Backplate Terminals: .110 [2.79]
  Switch Terminals: .187 [4.765] with .07 x .16 [1.8 x 3.8] slot

Snap-in Models, Filtered

Non-switched model shown, for switched detail refer to flange models
Metric fuse models have an additional jumper from filter to module

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Backplate Terminals: .110 [2.79]
  Switch Terminals: .187 [4.765] with .07 x .16 [1.8 x 3.8] slot

Case Dimensions

Part No. A B C D E F
(max.) ± .015 (max.) (max.) (max.) (max.)
± .381

Flange
Unfiltered

1.98 1.575 2.3 2.14 1.66 1.11
50.29 40.0 58.42 54.36 42.16 28.19

Snap-in
Unfiltered

1.28   2.3 2.14 1.66 1.11
32.51   58.42 54.36 42.16 28.19

Flange
Filtered

1.98 1.575 2.3 2.14 2.01 1.11
50.29 40.0 58.42 54.36 51.05 28.19
Snap-in
Filtered
1.28   2.3 2.14 2.01 1.11
32.51   58.42 54.36 51.05 28.19

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

2EDL

4EDL

6EDL

6EHL

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.05 .15 1 5 10 30

EDL Models
2A 6 14 24 40 45 50
4A 2 8 18 32 38 45
6A 1 6 17 31 37 45
EHL Models
6A 3 8 15 18 18 18

 
Current Rating Frequency - MHz
.05 .5 1 3 5 10 30

EDL Models
2A 7 16 21 23 37 47 50
4A 6 14 18 23 26 45 47
6A 6 15 20 25 24 45 50
EHL Models
6A 4 14 20 28 32 38 42

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.