| Dual Configuration Power Entry Module |
  
UL Recognized
CSA Certified
VDE Approved
Catalog Data Sheet
Printer friendly version |
|
 |
L Series
- Power entry module with switch or fuse
- For 10A capability and high performance filtering see the P Series
- Two element circuit provides extended EMI attenuation similar to EAB inlet filter
- North American or metric fuse holders
- Available with minimal leakage current for
medical applications (HL models)
Ordering Information

|
|
Specifications
| Maximum leakage current, each Line to Ground † : |
| |
|
DL
Models |
HL
Models |
| |
@ 120 VAC 60 Hz: |
0.25 mA |
2 µA |
| |
@ 250 VAC 50 Hz
|
0.50 mA |
5 µA |
| |
|
|
Hipot rating (one minute): |
| |
Line to Ground |
2250 VDC |
| |
Line to Line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Operating voltages: |
| |
1S & 1SC Suffix (fixed) |
250 VAC Max. |
| |
4 & 4C Suffix (selectable) |
100, 120, 220, 240 VAC |
| |
|
|
| Rated Current: |
| |
2EDL & 2EHL |
2A |
| Required Fuse(s): |
|
| |
North American: |
one .25 x 1.25"(not included)
|
| |
Metric: |
two 5 x 20mm (not included)
|
| |
|
| Switch: |
DPST
10,000 operations at 51A max. inrush |
Voltage Selection

To change selected voltage: disconnect the power cord; open cover using a small blade screwdriver or similar tool; insert the tool into the voltage selection slot and remove wheel from unit; select desired voltage; replace wheel into unit and close cover, making sure the selected voltage appears in connector window. |
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

LA303: Voltage Select Wheel, 3 position
Selection drum for use with L4 models.
Marked with 110V, 220V and 240V
LA304: Voltage Select Wheel, 4 position
Selection drum for use with L4 models.
Marked with 100V, 110V, 220V and 240V.
One LA304 comes standard with each L4 model.

LA400: Blank insert
Blank to replace switch in single voltage models
LA601: Insulating Boot
Plastic shroud to cover back of module to prevent inadvertent access
Replacement Fuse Holders
LA200: North American Fuseholder
Accommodates one .25 x 1.25" fuse
LA201: Metric Fuseholder
Accommodates one 5 x 20mm metric fuse

|
|
Electrical Schematics
DL Models
Single Voltage, Switched (DL1S)

4 Voltage Select, No-Switch (DL4)

HL Models
Single Voltage, Switched (HL1S)

4 Voltage Select, No-Switch (HL4)

|
| Case Styles |
Flange Models, Non-filtered

Switched model shown, for non-switched detail refer to snap-in models
| Typical Dimensions: |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Backplate Terminals: |
.110 [2.79] |
| |
Switch Terminals: |
.187 [4.765] with .07 x .16 [1.8 x 3.8] slot |
Flange Models, Filtered

Switched model shown, for non-switched detail refer to snap-in models
Metric fuse models have an additional jumper from filter to module
| Typical Dimensions: |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Backplate Terminals: |
.110 [2.79] |
| |
Switch Terminals: |
.187 [4.765] with .07 x .16 [1.8 x 3.8] slot |
Recommended Panel Cutouts

Notes:
(1) For panel thickness of .031 – .079 [0.8 – 2.0]
(2) For panel thickness of .083 – .126 [2.1 – 3.2]
(3) Mounting Holes .126 [3.20] Dia. for flange mounted versions only
(4) For Snap-In applications, the 1.12 [28.5] sides of the cutout must have a .02 [.508] radius on the installation side. Not required for flange mount versions.
|
|
Snap-in Models, Non-filtered

Non-switched model shown, for switched detail refer to flange models
| Typical Dimensions: |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Backplate Terminals: |
.110 [2.79] |
| |
Switch Terminals: |
.187 [4.765] with .07 x .16 [1.8 x 3.8] slot |
Snap-in Models, Filtered

Non-switched model shown, for switched detail refer to flange models
Metric fuse models have an additional jumper from filter to module
| Typical Dimensions: |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Backplate Terminals: |
.110 [2.79] |
| |
Switch Terminals: |
.187 [4.765] with .07 x .16 [1.8 x 3.8] slot |
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
F |
| (max.) |
± .015 |
(max.) |
(max.) |
(max.) |
(max.) |
| ± .381 |
Flange
Unfiltered
|
1.98 |
1.575 |
2.3 |
2.14 |
1.66 |
1.11 |
| 50.29 |
40.0 |
58.42 |
54.36 |
42.16 |
28.19 |
Snap-in
Unfiltered
|
1.28 |
|
2.3 |
2.14 |
1.66 |
1.11 |
| 32.51 |
|
58.42 |
54.36 |
42.16 |
28.19 |
Flange
Filtered
|
1.98 |
1.575 |
2.3 |
2.14 |
2.01 |
1.11 |
| 50.29 |
40.0 |
58.42 |
54.36 |
51.05 |
28.19 |
Snap-in
Filtered |
1.28 |
|
2.3 |
2.14 |
2.01 |
1.11 |
| 32.51 |
|
58.42 |
54.36 |
51.05 |
28.19 |
|
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
| |
2EDL

|
4EDL

|
6EDL

|
6EHL

|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
| Current Rating |
Frequency - MHz |
| .05 |
.15 |
1 |
5 |
10 |
30 |
|
| EDL Models |
| 2A |
6 |
14 |
24 |
40 |
45 |
50 |
| 4A |
2 |
8 |
18 |
32 |
38 |
45 |
| 6A |
1 |
6 |
17 |
31 |
37 |
45 |
| EHL Models |
| 6A |
3 |
8 |
15 |
18 |
18 |
18 |
|
|
|
| Current Rating |
Frequency - MHz |
| .05 |
.5 |
1 |
3 |
5 |
10 |
30 |
|
| EDL Models |
| 2A |
7 |
16 |
21 |
23 |
37 |
47 |
50 |
| 4A |
6 |
14 |
18 |
23 |
26 |
45 |
47 |
| 6A |
6 |
15 |
20 |
25 |
24 |
45 |
50 |
| EHL Models |
| 6A |
4 |
14 |
20 |
28 |
32 |
38 |
42 |
|
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |