Skip to content
Home > Series > PEM > P

P Series

The CHAMELEON Adaptable Module for General, High Performance or Medical Applications


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

P Series

The P series CHAMELEON power entry module offers the most popular features in a small footprint design.

As the first 10A module to provide all five power entry functions in one compact design, the chameleon module readily adapts to its environment and the needs of international markets.

  • Snap-in or flange mounting
  • Standard IEC 60321-1 C14 power inlet
  • Both North American and metric fusing capabilities
  • Two voltage selection options
    (for 4-voltage selection, see the M, L or LA Series)
  • Optional DPST on/off switch
  • Filter options for general purpose, medical and
    high-performance EMI filtering

The CHAMELEON module's compact design and modular construction allows selection of the required power entry feature — without altering the panel cutout. And the CHAMELEON module, with its optional adapters, will fit several common panel cutouts.

Filter Types

The CHAMELEON module has four filter and one non-filtered option:

S models provide an extended performance two element circuit EMI filter, with attenuation similar to the EEB Series power inlet filter. It offers protection for general purpose applications with stray Line to Ground and Line to Line noise that must be attenuated at the power inlet. These filters have limited leakage current and are available in current ratings of 3, 6 and 10A.

H models provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment.

L models feature a high performance medical filter designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models.

Z models provide a high performance three element differential mode circuit filter, with extended EMI attenuation similar to the M Series Z models, to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. For minimum depth behind the panel, see the M Series

B models are non-filtered and incorporate an interconnection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with an IEC connector and an optional switch to reduce external wiring. Compatible with the A or B RFI shield options.

 

 

Specifications

Maximum leakage current, each Line to Ground:
    H & L
Models
S & Z
Models
  @ 120 VAC 60 Hz: 2 µA .25 mA
  @ 250 VAC 50 Hz
5 µA .50 mA
     

Hipot rating (one minute):

  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated Voltage (max.): 250 VAC
     
Operating voltages: Selectable or Fixed
115 or 230 VAC
     
Rated Current: Non-filtered: 10 Amps
  Filtered: 3, 6 or 10 Amps
 
   
Fuseholder:

Accepts one or two fuses
.25" x 1.25" (not included)
or 5 x 20mm (not included)

   
Switch:

DPST
10,000 operations at 51A max. inrush

Electrical Schematic

H Model

S Model

L Model

Z Model

 

Ordering Information

Part numbers are constructed by selecting the alphanumeric character which represents the desired feature.
Note: For any option where shown as "0" use the digit ZERO (0) not the letter (O).



Available Part Numbers

Enter a full or partial part number to search for 3D CAD models, customer drawings, distributor stock status and eCommerce Links

Partial searches may take several seconds

Notes:

  1. Series extender cannot be added to units with a shield.
    No style of extender can be added to units with B or C shields.
  2. Dual voltage options are not available with L or Z Filter Types
  3. When using the interconnection block, the last 3 digits of the
    part number are BX (0, A, or B)
  4. High performance versions (L or Z filter types) are available
    with any switch or fuse option but only in 6 or 10A with
    horizontal (PE) or vertical (PM) mounting ears, single voltage (0), complete shield (C) and no extenders

* For alternative switch orientation options, please contact technical support or your Corcom product sales representative

The part number PS0SXSS6B would represent:

P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S)
general purpose filter (S) for 6A (6) with a B shield (B)

 

Voltage Selection

P series power entry modules include the voltage selector integral with the fuse holder. Three voltage selection options are each supported by one of three different fuse holders. The fifth digit of the part number specifies which of the three fuse holders is included to provide the desired voltage selection. The single voltage fuse holder (option "0") has no voltage indication markings. The dual voltage options select 115V or 230V by removing the fuse holder, flipping it over, and reinstalling it. Voltage selection is indicated through a window in the P Series door. The "SMPS" fuse holder (option "S") jumpers two independent P Series terminals to indicate 230V operation to a switching mode power supply. The "PRSR" parallel/serial fuse holder (option "X") connects the windings of the equipment's dual primary transformer (not included) to step down the voltage or double up the current. The markings on the voltage selection fuse holders also remind the user to install the appropriate fuse for the current at the selected voltage.

Input Voltage Selection Schemes

S - "SPMS" Jumper Type

X - "PRSR" Parallel / Serial Type for Dual Primary Transformer

Fuseholder

Another feature of the P series power entry module is the versatile fusing arrangement. The fuse holder can hold two 1/4" x 1-1/4" (3AG) or 5 x 20mm (metric) fuses. Single fusing is supported with a conversion clip that shorts one of the two fuse positions, and is designated by an S in the sixth part number digit. A module designated for a single fuse may be reconfigured by the manufacturer or the user to accept two fuses by simply removing the shorting clip. For applications intended for dual fusing, specify a D in the sixth part number digit.

Interconnection Block

Installation of the unfiltered versions of the P series requires wiring of the IEC socket terminals to the optional switch and the switch to the fuse holder. Labor can be eliminated by ordering the module with an interconnection block. This feature, designated by "BX" in the seventh and eighth digits, pre wires the module so that only connection to the equipment must be done during installation. The interconnection block includes a plastic case to prevent access to the internal connections.

The dimensions of this alternative are the same as the filtered versions.

 

 

Shield Options

The P series offers several RF shield options. The metal shield, optional on S, H and B filtered models, provides shielding from radiated emissions and provides an RF ground for the filter to the panel. This shield is available in two versions; a shield of the filter components (designated by an A as the final digit) and a complete shield (designated by B as the final digit).

The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from RFI coupling. This shield allows the use of the C or J extender.

The B shield covers the entire power entry module with metal, protecting the filter from RFI coupling, and covering the mounting cut-out to block RFI entering or leaving the equipment. The B shield cannot be used with any extender.

A complete metal enclosure is integral to both the high performance L and Z models, and must be specified by a C in the part number's final digit. This option is only available with the L or Z models.

Accessories

GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

PA100: Power interconnect assembly

For voltage select models. Designed for use with
either filtered or non-filtered units, 6" wire leads

PA101: Plug only
PA102: Pins only for use with PA101
PA105: Same as PA100 but with two wires for
units with no voltage selection

PA400: J Extender

Extends P Series height to fit J panel cutout

PA410: L Extender

Extends P Series width to fit L panel cutout

PA420: C Extender

Extends P Series height to fit C panel cutout

PA400 J Series Extender

C & L Extenders can not be used with B Shields.
L Extender can not be used with shields

 

 

 

 

Case Styles

Front View

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Mounting holes (2): .135 [3.43] Dia. with .23 [5.9] Dia. x 82 ° countersink for #4 flathead screw (PM, PE only)

Extender Options

Standard Models - Side and Rear View

Typical Dimensions:
  Terminals: .187 [4.8] with .055 [1.4] Dia. hole. Recommended for use with mating connectors - no solder
  Ground Terminal (1): .187 [4.8] with .112 x .06 [2.8 x 1.5] slot. Recommended for use with mating connectors - no solder

 

High Performance Models - Side and Rear View

Typical Dimensions:
  Terminals: .250 [6.4] with .07 [1.8] Dia. hole. Recommended for use with mating connectors - no solder
  Ground Terminal (1): .250 [6.4] with .16 x .07 [4.1 x 1.8] slot. Recommended for use with mating connectors - no solder

Shield Options

Note: Shields can only be used with filtered models. B shield may not be used with J or C extender

Recommended Panel Cutouts

Note:

For snap-in applications, the "A" sides must have a .020 [.508] radius on the installation side.
Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer's application parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels.

Style Dimension "A"
+.008 -.000
Dimension "B"
+.008 -.000
No Shield Shielded High Performance Standard High Performance
PM 1.06 [26.92] 1.12 [28.45] 1.12 [28.45] 2.13 [54.10] 2.201 [55.91]
PE 1.12 [28.45] 1.12 [28.45] 1.15 [29.21] 2.201 [55.91]* 2.201 [55.91]
PW 1.06 [26.92] 1.12 [28.45] - 2.201 [55.91]* -
PSC 1.06 [26.92] 1.12 [28.45] - 2.52 [64.01] -
PSJ 1.06 [26.92] 1.12 [28.45] - 2.60 [66.04] -
PSL 1.12 [28.45] - - 2.201 [55.91]* -
  *For panel thickness of 0.031 - 0.079 [0.787 - 2.01] only. Use 2.213 [56.21] for panel thickness of 0.083 - 0.114 [2.0 - 2.90]

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
S Models

3A

6A

10A

 

H Models

3A

6A

10A

 

L Models

6A

10A

 

 

Z Models

6A

10A

 

 

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.03 .1 15 .5 1 3 5 10 30

H Models
3A 7 17 21 27 30 29 26 23 15
6A - 8 11 15 17 19 18 16 13
10A 3 5 8 10 12 11 11 10 10
S Models
3A 7 17 21 27 33 40 44 50 32
6A - 8 12 17 23 32 36 44 30
10A - 3 5 10 13 23 27 35 27

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 5 10 30

Z Models
6A 8 21 27 30 37 43 49 52 42
10A 5 17 22 24 27 32 52 47 40
L Models
6A 8 21 27 29 34 35 25 21 16
10A 5 17 22 23 24 25 21 18 14

 
Current Rating Frequency - MHz
.10 .15 .5 1 3 5 10 30  

H Models
3A 2 4 12 18 31 40 48 41  
6A 2 4 12 16 26 35 40 35  
10A 2 4 12 16 26 33 40 32  
S Models
3A 2 4 12 15 30 48 50 45  
6A 2 4 12 15 22 42 55 45  
10A 2 4 12 15 22 42 55 45  

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 5 10 30

Z Models
6A 10 15 34 44 75 75 75 70 60
10A 10 20 20 35 67 75 75 70 60
L Models
6A 10 15 34 44 75 75 75 70 60
10A 10 20 20 35 67 75 75 70 60

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.