Skip to content
Home > Series > Power Line > FC

FC Series

Single Phase External Power Line Filter for Frequency Converters


UL Recognized

Catalog Data Sheet
Printer friendly version

 

FC Series

  • Designed for frequency inverters and variable speed motor drives
  • Suitable for electronically noisy environments
  • Protects programmable logic controllers from RF noise on the AC power line
  • Side flanges for easy mounting
  • Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

6FC10  
12FC10 12FC10B
16FC10 16FC10B
25FC10 25FC10B
36FC10 36FC10B
50FC10 50FC10B

 

 

Specifications

Maximum leakage current, each Line to Ground:
    B suffix no suffix
  @ 120 VAC 60 Hz 3.9 mA 3.8 mA
  @ 250 VAC 50 Hz 7.0 mA 6.7 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 6A to 50A *
  * refer to part number for rating
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematics

FC10

FC10B

 

Case Styles

6, 12, 16FC10

Typical Dimensions:  
  Line/Load Terminals (4): DIN type accepts 10AWG solid / 12AWG stranded
  Ground Terminals (2): 8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[..22]
  Mounting Holes (4): .203 x .156 [5.16 x 3.96]

25, 36FC10

Typical Dimensions:  
  Line/Load Terminals (4): DIN type accepts 8AWG solid / 10AWG stranded
  Ground Terminals (2): 8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[..22]
  Mounting Slots (4): .260 [6.6] wide

 

 

Case Dimensions

Part No. A B C D E F
(max.) (max.) (max.) ± .020 (max.) ± .010
± .51 ± .254
6FC10 4.60 3.10 1.78 2.677 3.70 2.00
116.8 78.7 45.21 67.8 94.0 50.8

12FC10/10B
16FC10/10B
5.47 3.96 2.18 3.50 4.53 2.00
139.0 100.6 55.4 88.9 114.8 50.8

25, 36, 50
FC10/FC10B
6.90 5.48 2.55 4.90 5.94 2.756
175.3 139.2 64.77 124.5 150.9 70.0

 

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

6FC10

12FC10

16FC10

25FC10

36, 50FC10

12, 16FC10B

25FC10B

36FC10B

50FC10B

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Part No. Frequency - MHz
.01 .03 .05 .1 .5 1 5 10 30

6FC10 9 19 26 37 65 65 50 40 35
12FC10 5 17 25 37 65 65 65 60 35
16FC10 4 15 22 36 65 65 70 70 35
25FC10 2 14 22 36 75 75 70 70 48
36, 50FC10 - 6 14 27 68 75 70 70 50
12, 16FC10B 16 28 37 50 81 76 63 55 38
25FC10B 14 25 36 49 91 88 71 64 46
36FC10B 11 25 37 50 81 87 73 66 49
50FC10B 11 24 36 49 81 75 62 54 37

 
Part No. Frequency - MHz
.01 .03 .05 .1 .5 1 5 10 30

6FC10 10 10 35 60 75 75 60 50 45
12FC10 14 14 30 51 75 75 75 70 45
16FC10 14 14 29 55 75 75 75 70 45
25FC10 14 14 17 42 75 75 70 70 50
36, 50FC10 14 14 17 42 75 75 70 70 50
12, 16FC10B 30 32 46 64 91 86 77 78 65
25FC10B 24 24 31 46 92 87 86 75 55
36FC10B 27 33 27 41 89 88 82 74 55
50FC10B 30 32 48 64 91 87 82 79 67

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.