SK Series
- Designed to reduce conducted noise to acceptable limits for equipment that must comply with FCC / EN specifications
- Utilizes significantly higher element values than the general purpose K Series which makes them better suited for equipment with Line to Ground and Line to Line conducted emissions including those with switching power supplies
- ESK6C and VSK6C incorporate separate ground circuit inductor to isolate the equipment chassis from power line ground at RF frequencies
Ordering Information

*1-15A: IEC 60320-1 C14 inlet mates with C13 connector
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
|
VSK Models |
ESK Models |
| |
3, 6 & 10 Amps |
|
|
| |
@ 120 VAC 60 Hz |
.4mA |
.21mA |
| |
@ 250 VAC 50 Hz |
.7 mA |
.36 mA |
| |
|
|
|
| |
20, 30 & 40 Amps |
|
|
| |
@ 120 VAC 60 Hz |
.75 mA |
.3 mA |
| |
@ 250 VAC 50 Hz |
1.25 mA |
.5 mA |
| |
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
2250 VDC |
| |
Line to Line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
250 VAC |
| |
|
|
| Rated Current: |
3A to 40A |
| |
|
| Operating Ambient Temperature Range (at rated current Ir): |
| |
|
-10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45
|
Electrical Schematic

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

|
SK1

| Typical Dimensions: |
| |
Line/Load Terminals(4): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
SK3 (3A)

| Typical Dimensions: |
|
| |
Wire leads (5): |
.4.0 [101.6] Min. AWG18 |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
SK3 (6A)

| Typical Dimensions: |
|
| |
Wire leads (5): |
.4.0 [101.6] Min. AWG18 (AWG16 for 10A) |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
SK6 (20A)

| Typical Dimensions: |
|
| |
Terminals (5): |
8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[.22] |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
SK6 (30A)

| Typical Dimensions: |
|
| |
Terminals (5): |
10-32
Torque 27 lbf-in. [3.05 N-m] max. ±2[.22] |
| |
Mounting Slots (4): |
.250 x .156 [6.35 x 3.96] Dia. |
SK6C (30A)

| Typical Dimensions: |
|
| |
Terminals (5): |
10-32
Torque 27 lbf-in. [3.05 N-m] max. ±2[.22] |
| |
Mounting Slots (4): |
.250 x .156 [6.35 x 3.96] Dia. |
|
|
SK6 (40A)

| Typical Dimensions: |
|
| |
Terminals (5): |
10-32
Torque 27 lbf-in. [3.05 N-m] max. ±2[.22] |
| |
Mounting Slots (4): |
.156 x .203 [3.96 x 5.15] Dia. |
SK7 & SK7M (metric inserts)

| Typical Dimensions: |
| |
Load Terminals(2): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Line Inlet (1): |
IEC 60320-1 C14 |
| |
K7 Inserts (2): |
6-32 x 1/4 |
| |
K7M Inserts (2): |
M3x.5 |
Recommended Panel Cutouts
tolerance ± .005 [0.13]
Back mount only
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
± .015** |
(max.) |
| ± .38 |
| 3VSK1, 3ESK1 |
3.85 |
2.07 |
1.16 |
2.938 |
3.35 |
| 97.8 |
52.6 |
29.5 |
74.63 |
85.1 |
|
| 3VSK3, 3ESK3 |
2.56 |
2.07 |
1.16 |
2.938 |
3.35 |
| 65.0 |
52.6 |
29.5 |
74.63 |
85.1 |
|
3VSK7, 3VSK7M,
3ESK7, 3ESK7M |
3.21 |
2.25 |
1.53 |
1.575 |
.063* |
| 81.5 |
57.2 |
38.9 |
40.01 |
16.0* |
|
| 6VSK1, 6ESK1 |
4.34 |
2.25 |
1.28 |
3.427 |
3.83 |
| 110.2 |
57.2 |
32.5 |
87.05 |
97.3 |
|
6VSK3, 6ESK3 |
3.05 |
2.25 |
1.28 |
3.427 |
3.83 |
| 77.5 |
57.2 |
32.5 |
87.05 |
97.3 |
|
6VSK7, 6VSK7M,
6ESK7, 6ESK7M |
3.21 |
2.25 |
1.78 |
1.575 |
0.63* |
| 81.5 |
57.2 |
45.2 |
40.01 |
16.0* |
|
| 10VSK1, 10ESK1 |
4.97 |
2.25 |
1.78 |
4.063 |
4.46 |
| 126.2 |
57.2 |
45.2 |
103.2 |
113.3 |
|
| 10VSK3, 10ESK3 |
3.69 |
2.25 |
1.78 |
4.063 |
4.46 |
| 93.7 |
57.2 |
45.2 |
103.2 |
113.3 |
|
10VSK7, 10ESK7M,
10ESK7, 10ESK7M |
4.34 |
2.25 |
1.78 |
1.575 |
0.63* |
| 110.0 |
57.2 |
45.2 |
40.01 |
16.0* |
|
| 20ESK6, 20VSK6 |
5.09 |
2.25 |
1.78 |
4.063 |
4.46 |
| 127.3 |
57.2 |
45.2 |
103.2 |
129.3 |
|
30ESK6, 30ESK6C,
30VSK6, 30VSK6C |
4.92 |
3.12 |
2.75 |
3.437 |
4.00 |
| 125.0 |
79.25 |
69.85 |
87.3 |
101.6 |
|
| 40VSK6 |
6.00 |
3.12 |
2.18 |
3.50 |
3.96 |
| 152.4 |
79.25 |
55.4 |
88.9 |
100.6 |
|
| * ± .02 [.05] |
| ** For 30A & 40A ± .020 [.51] |
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
3 & 6VSK

|
10 & 20VSK

|
30VSK

|
40VSK

|
3 & 6 ESK

|
10 & 20 ESK

|
30ESK

|
|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
| Current Rating |
Frequency - MHz |
| .01 |
.08 |
.1 |
.15 |
.5 |
1 |
5 |
10 |
30 |
|
| VSK Models |
| 3A, 6A, 10A |
4 |
23 |
25 |
29 |
43 |
44 |
42 |
42 |
30 |
| 20A |
7 |
23 |
25 |
29 |
43 |
44 |
48 |
48 |
48 |
| 30A |
2 |
13 |
14 |
15 |
27 |
31 |
46 |
51 |
39 |
| 40A |
2 |
15 |
18 |
22 |
40 |
43 |
45 |
50 |
30 |
| ESK Models |
| 3A, 6A, 10A |
4 |
22 |
24 |
28 |
42 |
40 |
36 |
36 |
27 |
| 20A |
7 |
22 |
24 |
28 |
35 |
38 |
45 |
45 |
45 |
| 30A |
2 |
13 |
15 |
15 |
27 |
31 |
40 |
41 |
36 |
|
|
|
| Current Rating |
Frequency - MHz |
| .01 |
.08 |
.1 |
.15 |
.5 |
1 |
5 |
10 |
30 |
|
| VSK Models |
| 3A, 6A |
1 |
3 |
10 |
25 |
59 |
65 |
62 |
40 |
40 |
| 10A |
1 |
3 |
3 |
10 |
55 |
65 |
65 |
50 |
50 |
| 20A |
1 |
10 |
8 |
8 |
45 |
60 |
65 |
60 |
60 |
| 30A |
5 |
13 |
13 |
13 |
60 |
60 |
51 |
43 |
43 |
| 40A |
7 |
14 |
16 |
30 |
65 |
65 |
65 |
57 |
50 |
| ESK Models |
| 3A, 6A |
1 |
3 |
10 |
25 |
59 |
65 |
62 |
40 |
40 |
| 10A |
1 |
3 |
3 |
10 |
55 |
65 |
65 |
65 |
45 |
| 20A |
1 |
10 |
8 |
8 |
45 |
60 |
65 |
60 |
60 |
| 30A |
5 |
12 |
12 |
13 |
60 |
60 |
51 |
43 |
43 |
|
|
|