Skip to content
Home > Series > Power Line > WG

WG Series

High Performance, Low Cost Filter Ideal for Appliance Equipment


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet

 

WG Series

  • Cost-effective
  • Tubular design
  • WGA, WGB and WGC versions designed to comply with leakage current for fixed appliances not easily moved from one place to another
  • WGD, WGE and WGF versions designed to comply with leakage current requirements for appliances which may be easily moved from one place to another
  • Available in a variety of styles

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

16WGA1 16WGD1
16WGB1 16WGE1
16WGC1 16WGF1
16WGA3 16WGD3
16WGB3 16WGE3
16WGC3 16WGF3
16WGA7 16WGD7
16WGB7 16WGE7
16WGC7 16WGF7

 

 

Specifications

Maximum leakage current, each Line to Ground:
    A, B & C
Models
D, E & F
Models
  @ 120 VAC 60 Hz 0.76 mA 0.10 mA
  @ 250 VAC 50 Hz
1.27mA 0.20 mA
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 16 Amps
 
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematics

Style 1 and 3

Style 7 (RAST 5 Connector)

 

Case Styles

WG_1

Typical Dimensions:
  Terminals(5): .250 [6.3] with .07 [1.8] Dia. hole
  Mounting Stud(1): M8 x 1.25

WG_3

Typical Dimensions:
  Wire Leads(5): 4.0 [101.6] min. 18AWG UL1015
  Mounting Stud(1): M8 x 1.25
     
Wire Colors:  
  L(2): Brown
  N(4): Blue
  U(1): Brown
  Gnd: Green / Yellow
  U(3): Blue

 

WG_7

Typical Dimensions:
  Terminals(3): .250 [6.3] with .07 [1.8] Dia. hole
  RAST 5: Unkeyed RAST 5 Header interface*
  Mounting Stud(1): M8 x 1.25

* The RAST 5 interface mates with any two-position (keyed or unkeyed) TE Connectivity
Standard Power Timer connector or RAST 5 Positive Lock Mark III connector

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
All Case Styles

16WGA

16WGB

16WGC

16WGD

16WGE

16WGF

 

 
Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.05 .1 .15 .5 1 2 5 10 20 30

16WGA 3 10 14 33 41 47 54 50 37 30
16WGB 11 16 21 33 39 44 53 55 37 30
16WGC 12 18 22 34 41 46 51 52 34 27
16WBD 3 8 11 22 26 31 31 33 40 44
16WGE 5 12 15 21 23 25 31 32 37 45
16WGF 9 14 18 24 26 28 31 32 37 44

 
Current Rating Frequency - MHz
.05 .1 .15 .5 1 2 5 10 20 30

16WGA 14 19 22 33 41 51 47 42 48 50
16WGB 14 19 22 33 41 51 50 45 52 45
16WGC 13 19 22 33 40 50 58 42 48 42
16WBD 13 19 22 33 40 48 58 57 54 45
16WGE 13 19 22 33 40 48 58 57 51 45
16WGF 13 19 22 33 40 49 58 59 50 44

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.