Skip to content
Home > Series > Power Line > XYZ

X, Y, Z Series

Chassis or PC Board Mountable Power Line Filters for Emission Control


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

X, Y, Z Series

  • Compact chassis or PC board mountable
  • Three levels of performance
  • Complete filtering solution in minimal size

X Series – Designed to bring most digital equipment (including those with switching power supplies) into compliance with FCC Part 15J, Class B conducted emission limits

Y Series – Designed to bring most digital equipment (including those with switching power supplies) into compliance with EN55022, Level A and FCC Part 15J, Class B conducted emission limits

Z Series – Designed to bring most digital equipment (including those with switching power supplies) into compliance with EN55022, Level B and FCC Part 15J, Class B conducted emission limits

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

3EXP 1EZP
3EX1 2EZP
4EXP 3EZP
6EXP 3EZ1
2EYP  
3EYP  
4EYP

 

 

Specifications

Maximum leakage current, each Line to Ground:
  @ 120 VAC 60 Hz .30 mA
  @ 250 VAC 50 Hz
.50 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 3 to 6A
   
Operating Ambient Temperature Range (at rated current Ir):
  -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

 

Case Styles

X1 & Z1

Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .188 [4.75] Dia.

XP, YP & ZP

Typical Dimensions:
  Pins (5): 0.065 [1.65] square

 

 

Recommended Mounting Holes and Clearance Area

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .015 (max.)
± .38
3EXP 2.61 1.13 1.62    
66.3 28.7 41.1    

3EX1 3.01 1.84 1.16 2.375 2.79
79.7 46.8 29.46 60.33 70.87

4EXP 2.61 1.13 1.62    
66.3 28.7 41.1    

6EXP 2.61 1.13 1.75    
66.3 28.7 44.5    

2EYP 2.61 1.13 1.62    
66.3 28.7 41.1    

3EYP, 4EYP 2.61 1.13 1.75    
66.3 28.7 44.5    

1EZP 2.61 1.13 1.62    
66.3 28.7 41.1    

2EZP, 3EZP 2.61 1.13 1.75    
66.3 28.7 44.5    

3EZ1 3.54 2.08 1.31 2.938 3.35
89.9 52.8 33.3 74.63 85.1

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

3EX

4EX

6EX

2EY

3EY

4EY

1EZ

2EZ

3EZ

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.01 .05 .15 .5 1 5 10 30

EX Models
3A 2 13 21 35 46 44 44 44
4A 2 13 22 38 44 44 44 38
6A 2 11 20 35 40 40 40 36
EY Models
2A 8 21 31 49 44 40 40 40
3A 11 24 36 43 40 40 40 40
4A 5 18 28 45 40 40 40 36
EZ Models
1A 18 32 43 47 44 43 43 45
2A 18 32 45 41 40 40 40 40
3A 15 29 39 43 42 40 40 40

 
Current Rating Frequency - MHz
.02 .03 .05 .07 .15 ..5 1 5 10 30

EX Models
3A - - - 5 34 60 65 60 45 50
4A - - - 10 37 70 70 70 65 55
6A - - - 3 31 65 70 70 60 55
EY Models
2A - - 10 19 40 70 75 70 60 55
3A - - 10 20 42 68 68 67 62 50
4A - - 6 18 41 67 75 70 65 55
EZ Models
1A 7 29 34 43 62 70 70 70 60 55
2A 2 15 31 40 57 75 70 65 55 50
3A - 10 26 34 53 75 75 70 60 55

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.